Home Brands Schneider Electric Schneider TeSys Deca (LC1D) Contactors TeSys Deca — the LC1D range — is the most widely installed contactor ian panels, covering motor switching from 9 A up to 150 A. We supply LC1D contactors in all common coil voltages, LC2D reversing assemblies, LAD auxiliary contact blocks and mechanical interlocks, and the LRD thermal overload relays that mount directly beneath them.
TeSys Deca Contactors (LC1D) we supply LAD9V6 Reversing Contactor Busbar Kit for TeSys D LC1D65AB7 contactor 65 A AC-3 3P with 24V AC coil LC2D18BD Reversing Contactor, TeSys Deca, 3P 18A AC-3, 24V DC Coil LC2D18BL reversing contactor 18A AC-3 3P with 24V DC low consumption coil Schneider Electric GV2L04 — TeSys GV2L Motor Circuit Breaker 3P 0.63A Magnetic Rotary Handle Screw Clamp Terminals Schneider Electric GV2L05 — TeSys Deca GV2L motor circuit breaker 3P 1A magnetic rotary handle screw clamp Schneider Electric GV2L06 — Motor circuit breaker 3P 1.6A magnetic rotary handle screw clamp terminals Schneider Electric GV2L07 — TeSys GV2L Motor Circuit Breaker 3P 2.5A Magnetic Rotary Handle Schneider Electric GV2L08 — TeSys Deca GV2L motor circuit breaker 3P 4A magnetic rotary handle screw clamp Schneider Electric GV2L10 — TeSys Deca Motor Circuit Breaker, 3P, 6.3A, Magnetic, Rotary Handle, Screw Clamp Terminals Schneider Electric GV2L14 — TeSys GV2L Motor Circuit Breaker 3P 10A Magnetic Rotary Handle Schneider Electric GV2L20 — TeSys Deca GV2L motor circuit breaker 3P 18A magnetic rotary handle Schneider Electric GV2L22 — TeSys GV2L Motor Circuit Breaker 3P 25A Magnetic Rotary Handle Screw Clamp Schneider Electric GV2L32 — TeSys GV2L Motor Circuit Breaker, 3P 32A Magnetic, Rotary Handle, Screw Clamp Schneider Electric GV2ME01 — TeSys Deca Motor Circuit Breaker 3P 0.1-0.16A Thermal Magnetic Schneider Electric GV2ME03 — TeSys GV2 motor circuit breaker 3P 0.25-0.4A thermal magnetic screw clamp button control Schneider Electric GV2ME05 — TeSys GV2ME motor circuit breaker 3P 0.63-1A thermal-magnetic Schneider Electric GV2P01 — TeSys GV2 Motor Circuit Breaker 0.1-0.16A 3P Thermal-Magnetic Schneider Electric GV2P03 — TeSys Deca motor circuit breaker 3P 0.25-0.4A thermal magnetic screw clamp rotary handle Schneider Electric GV2P04 — TeSys Deca Motor circuit breaker, 3P, 0.4-0.63A, thermal magnetic, screw clamp, rotary handle Schneider Electric GV2P05 — TeSys Deca motor circuit breaker 3P 0.63-1A thermal magnetic Schneider Electric GV2P06 — TeSys Deca GV2P Motor Circuit Breaker 3P 1 to 1.6A Thermal Magnetic Screw Clamp Rotary Handle Schneider Electric GV2P07 — TeSys GV2 motor circuit breaker 3P 1.6-2.5A thermal magnetic Schneider Electric GV2P08 — TeSys Deca Motor circuit breaker 3P 2.5-4A thermal magnetic screw clamp rotary handle Schneider Electric GV2P14 — TeSys Deca Motor Circuit Breaker 3P 6-10A Thermal Magnetic Screw Clamp Rotary Handle Schneider Electric GV2P20 — TeSys Deca 3P motor circuit breaker 13-18A thermal magnetic rotary handle Schneider Electric GV2P21 — TeSys Deca GV2 Motor Circuit Breaker 17-23A 3P Thermal Magnetic Rotary Handle Schneider Electric GV2P22 — TeSys Deca Motor Circuit Breaker 3P 20-25A Thermal Magnetic Rotary Handle Schneider Electric GV2P32 — TeSys Deca GV2 Motor Circuit Breaker 3P 24-32A Thermal Magnetic Schneider Electric GV3P25 — TeSys GV3P Motor Circuit Breaker, 3P, 17-25A Thermal-Magnetic, EverLink Terminals Schneider Electric GV3P50 — TeSys GV3 Motor Circuit Breaker 3P 37-50A Thermal Magnetic Schneider Electric GV3P65 — TeSys Deca GV3 Motor Circuit Breaker 65 A Schneider Electric GV3P73 — TeSys GV3P motor circuit breaker 3P 62-73A thermal magnetic with EverLink terminals Schneider Electric LAD9R1 — Kit for assembling 3P reversing contactors, LC1D09-D38 with screw clamp terminals, without electrical interlock Schneider Electric LADN04 — Auxiliary contact block, TeSys Deca, 4NC, front mounting, screw clamp Schneider Electric LADN11 — TeSys Deca Auxiliary Contact Block, 1NO + 1NC, Front Mounting, Screw Clamp Terminals Schneider Electric LADN13 — Auxiliary Contact Block, TeSys Deca, 1NO + 3NC, Front Mount, Screw Clamp Terminals Schneider Electric LADN20 — TeSys Deca Auxiliary Contact Block 2NO Front Mounting Screw Clamp Terminals Schneider Electric LADN22 — TeSys Deca Auxiliary Contact Block 2NO + 2NC Schneider Electric LADN31 — Auxiliary contact block, 3NO + 1NC, front mounting, screw clamp terminals Schneider Electric LADN40 — TeSys Deca Auxiliary Contact Block, 4 NO, Front Mounting, Screw Clamp Terminals Schneider Electric LC1D066BD — Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 6A, 24VDC coil Schneider Electric LC1D066F7 — Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 6A, 110VAC 50/60Hz coil Schneider Electric LC1D066M7 — Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 6A, 220VAC 50/60Hz coil Schneider Electric LC1D093B7 — Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 9A, 24V AC 50/60Hz coil, spring terminals Schneider Electric LC1D093BD — TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V DC coil Schneider Electric LC1D093BL — Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 9A, 24V DC low consumption coil, spring terminals Schneider Electric LC1D093E7 — Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 9A, 48V AC 50/60Hz coil, spring terminals 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Next
What to check before ordering The coil voltage code is the last part of the reference: B7 is 24 V AC, BD 24 V DC, M7 220 V AC, F7 110 V AC. Getting it wrong is the single most common ordering error. Choose the AC-3 rating from the motor's full-load current, then confirm the contactor's rated operational current at your ambient temperature. Standard LC1D units include 1NO+1NC auxiliary contacts; add LADN blocks if your control scheme needs more. For reversing duty use an LC2D assembly or fit a mechanical interlock — two loose contactors are not safe on their own. Frequently asked questions What does the suffix on an LC1D09 part number mean? It is the coil voltage. LC1D09B7 is 24 V AC, LC1D09BD is 24 V DC, LC1D09M7 is 220 V AC and LC1D09F7 is 110 V AC — the power side is identical. Always confirm the coil supply before ordering.
Which LRD overload relay fits my LC1D contactor? LRD relays mount directly onto LC1D contactors of the matching frame size, and are chosen by current-setting range around the motor's full-load current.
Request a quote