Home Brands Schneider Electric Schneider Acti9 iID RCCB The Acti9 iID is Schneider's modular residual current circuit breaker, sold under A9R references and used for earth-leakage protection in distribution boards. We supply 2-pole and 4-pole devices in 30 mA personal-protection and 300 mA fire-protection sensitivities, in type AC, type A and the SI ('super-immunised') variants specified where nuisance tripping is a problem.
Acti9 iID RCCB Residual Current Devices we supply Acti9 iID A9R74440 4-pole 40 A 300 mA type AC residual current circuit breaker Acti9 iID A9R81240 2-pole 40 A 30 mA type AC residual current circuit breaker Schneider Electric A9R10216 — Interruptor Diferencial IDR Acti9 ilD 2P, 16A, 10mA, 10kA, 220/240VCA, Classe AC Schneider Electric A9R11291 — Interruptor Diferencial IDR Acti9 ilD 2P, 100A, 30mA, 10kA, 220/240VCA, Classe AC Schneider Electric A9R11463 — Acti9 iID RCCB, 4P, 63A, AC type, 30mA Schneider Electric A9R11491 — Acti 9 iID - RCCB - 4P - 100A - 30mA - type AC Schneider Electric A9R12480 — Residual current circuit breaker (RCCB), 4P, 80A, AC type, 100mA Schneider Electric A9R12491 — Interruptor Diferencial IDR Acti9 ilD 4P, 100A, 100mA, 10kA, 380/415VCA, Classe AC Schneider Electric A9R14280 — Acti9 iID RCCB 2P 80A AC Type 300mA Schneider Electric A9R15480 — Residual current circuit breaker (RCCB), iID, 4P, 80A, AC type, 300mA, selective Schneider Electric A9R16440 — Interruptor Diferencial IDR Acti9 ilD 4P, 40A, 500mA, 10kA, 380/415VCA, Classe AC Schneider Electric A9R17463 — Interruptor Diferencial IDR Acti9 ilD 4P, 63A, 500mA-S, 10kA, 380/415VCA Classe AC Schneider Electric A9R30225 — Interruptor Diferencial IDR Acti9 ilD 2P, 25A, 10mA, 10kA, 220/240VCA, Classe A-SI Schneider Electric A9R31480 — Interruptor Diferencial IDR Acti9 ilD 4P, 80A, 30mA, 10kA, 380/415VCA, Classe A-SI Schneider Electric A9R31491 — Interruptor Diferencial IDR Acti9 ilD 4P, 100A, 30mA, 10kA, 380/415VCA, Classe A-SI Schneider Electric A9R35240 — Interruptor Diferencial IDR Acti9 ilD 2P, 40A, 300mA-S, 10kA, 220/240VCA, Classe A-SI Schneider Electric A9R35263 — Interruptor Diferencial IDR Acti9 ilD 2P, 63A, 300mA-S, 10kA, 220/240VCA, Classe A-SI Schneider Electric A9R35440 — Interruptor Diferencial IDR Acti9 ilD 4P, 40A, 300mA-S, 10kA, 380/415VCA, Classe A-SI Schneider Electric A9R35491 — Interruptor Diferencial IDR Acti9 ilD 4P, 100A, 300mA-S, 10kA, 380/415VCA, Classe A-SI Schneider Electric A9R41225 — Acti9 iID Residual Current Circuit Breaker 2P 25A AC 30mA Schneider Electric A9R41240 — iID Residual Current Circuit Breaker (RCCB), 2P 40A, AC Type 30mA Schneider Electric A9R41263 — Residual Current Circuit Breaker (RCCB) iID 2P 63A AC 30mA Schneider Electric A9R41425 — Residual Current Circuit Breaker iID 4P 25A AC 30mA Schneider Electric A9R41463 — Acti9 iID RCCB 4P 63A 30mA AC type Schneider Electric A9R50225 — Residual current circuit breaker (RCCB) 2P 25A AC 30mA Schneider Electric A9R50240 — Residual current circuit breaker (RCCB) Acti9 iID K, 2P, 40A, AC type, 30mA Schneider Electric A9R50425 — Residual Current Circuit Breaker (RCCB) 4P 25A 30mA AC Type Schneider Electric A9R51240 — Acti9 iID Residual Current Circuit Breaker 2P 40A Type A 30mA Schneider Electric A9R51263 — Residual Current Circuit Breaker (RCCB) 2P 63A Type A 30MA Schneider Electric A9R51440 — Residual Current Circuit Breaker (RCCB) iID, 4P, 40A, Type A, 30mA Schneider Electric A9R60240 — Residual Current Circuit Breaker (RCCB) 2P 40A AC Type 30mA Schneider Electric A9R61425 — Residual current circuit breaker (RCCB) 4P 25A A-SI Type 30mA Schneider Electric A9R61440 — Residual Current Circuit Breaker (RCCB) 4P 40A A-SI Type 30mA Schneider Electric A9R71225 — Interruptor Diferencial IDR Acti9 ilD 2P, 25A, 30mA, 10kA, 220/240VCA, Classe AC Schneider Electric A9R71240 — Interruptor Diferencial IDR Acti9 ilD 2P, 40A, 30mA, 10kA, 220/240VCA, Classe AC Schneider Electric A9R71263 — Interruptor Diferencial IDR Acti9 ilD 2P, 63A, 30mA, 10kA, 220/240VCA, Classe AC Schneider Electric A9R71425 — Interruptor Diferencial IDR Acti9 ilD 4P, 25A, 30mA, 10kA, 380/415VCA, Classe AC Schneider Electric A9R71440 — Interruptor Diferencial IDR Acti9 ilD 4P, 40A, 30mA, 10kA, 380/415VCA, Classe AC Schneider Electric A9R71463 — Interruptor Diferencial IDR Acti9 ilD 4P, 63A, 30mA, 10kA, 380/415VCA, Classe AC Schneider Electric A9R74225 — Interruptor Diferencial IDR Acti9 ilD 2P, 25A, 300mA, 10kA, 220/240VCA, Classe AC Schneider Electric A9R74240 — Interruptor Diferencial IDR Acti9 ilD 2P, 40A, 300mA, 10kA, 220/240VCA, Classe AC Schneider Electric A9R74425 — Interruptor Diferencial IDR Acti9 ilD 4P, 25A, 300mA, 10kA, 380/415VCA, Classe AC Schneider Electric A9R74463 — Interruptor Diferencial IDR Acti9 ilD 4P, 63A, 300mA, 10kA, 380/415VCA, Classe AC Schneider Electric A9R91240 — Interruptor Diferencial IDR Acti9 ilD 2P, 40A, 30mA, 10kA, 220/240VCA, Classe A-SI Schneider Electric A9R91425 — Interruptor Diferencial IDR Acti9 ilD 4P, 25A, 30mA, 10kA, 380/415VCA, Classe A-SI Schneider Electric A9R91440 — Interruptor Diferencial IDR Acti9 ilD 4P, 40A, 30mA, 10kA, 380/415VCA, Classe A-SI Schneider Electric A9R91463 — Interruptor Diferencial IDR Acti9 ilD 4P, 63A, 30mA, 10kA, 380/415VCA, Classe A-SI Schneider Electric A9Z51216 — Interruptor Diferencial IDR Acti9 ilD 2P, 16A, 30mA, 10kA, 230VCA, Classe B-EV 1 2 Next
What to check before ordering Sensitivity: 30 mA protects people; 300 mA protects against fire and is normally used upstream. Type AC detects sinusoidal leakage only; type A also detects pulsating DC and is required where drives and electronics are fed. SI versions resist nuisance tripping from transient leakage and high-frequency noise — worth it on drive-heavy boards. An RCCB provides no overload protection: it must be backed by MCBs. Frequently asked questions What does the SI in iID SI mean? Super-immunised. These devices are hardened against nuisance tripping from transients, surge and high-frequency leakage, which makes them the practical choice on boards feeding VFDs, switch-mode supplies or long cable runs.
Do I need an RCCB if I already have RCBOs? Not usually on the same circuits — an RCBO already combines earth-leakage and overcurrent protection per circuit. An upstream 300 mA RCCB is still often specified for fire protection on the incomer.
Why is my RCCB tripping intermittently? Most often accumulated standing leakage across many circuits rather than one fault, especially with drives and electronics. Splitting the board across more RCDs or moving to type A / SI devices usually resolves it.