Home Products Schneider Electric C40F44V400 Schneider Electric C40F44V400 Circuit breaker ComPacT NSX400F, 36kA at 415VAC, MicroLogic 4.3 Vigi trip unit 400A, 4 poles 4d. Official Schneider characteristics include Range: ComPacT; Product name: ComPacT NSX; Device short name: NSX400F; Product or component type: Earth leakage circuit breaker; Device application: Distribution; Poles description: 4P; Protected poles description: 4D 3D + N/2 3D; Neutral position: Left.
Details Brand: Schneider Electric Part number: C40F44V400 Series: ComPacT NSX Category: Earth leakage circuit breaker Related Schneider Electric parts Schneider Electric C40F47E400 — Circuit breaker ComPacT NSX400F, 36kA at 415VAC, MicroLogic 7.3 E Vigi trip unit 400A, 4 poles 4d Schneider Electric C40F4TM400 — ComPacT NSX400F - Disjoncteur - TM-D 400A - 4P4D - 36kA circuit breaker;Compact NSX;MicroLogic 1.3;3 poles;320 A;415 VAC;C40H31M320 circuit breaker;Compact NSX;MicroLogic 2.3;3 poles;250 A;415 VAC;C40H32D250 circuit breaker;Compact NSX;MicroLogic 2.3;3 poles;320 A;415 VAC;C40H32M320 Schneider Electric C40H34V400 — Circuit breaker ComPacT NSX400H, 70kA at 415VAC, MicroLogic 4.3 Vigi trip unit 400A, 3 poles 3d Schneider Electric C40H37E400 — Circuit breaker ComPacT NSX400H, 70kA at 415VAC, MicroLogic 7.3 E Vigi trip unit 400A, 3 poles 3d Schneider Electric C40H3TM400 — ComPacT NSX400H - Disjoncteur - TM-D 400A - 3P3D - 70kA circuit breaker;Compact NSX;MicroLogic 2.3;4 poles;250 A;415 VAC;C40H42D250 circuit breaker;Compact NSX;MicroLogic 2.3;4 poles;400 A;415 VAC;C40H42D400 Schneider Electric C40H44V400 — Circuit breaker ComPacT NSX400H, 70kA at 415VAC, MicroLogic 4.3 Vigi trip unit 400A, 4 poles 4d Schneider Electric C40H47E400 — Circuit breaker ComPacT NSX400H, 70kA at 415VAC, MicroLogic 7.3 E Vigi trip unit 400A, 4 poles 4d Request a quote for C40F44V400
Specifications Range ComPacT Network type AC Product name ComPacT NSX Neutral position Left Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 35 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 20 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1 Device short name NSX400F Network frequency 50/60 Hz Poles description 4P Device application Distribution [In] rated current 400 A at 40 °C Utilisation category Category A Breaking capacity code F 36 kA 415 V AC Manufacturer part number C40F44V400 Product or component type Earth leakage circuit breaker Suitability for isolation Yes conforming to EN/IEC 60947-2 Protected poles description 4D 3D + N/2 3D [Ue] rated operational voltage 440 V AC 50/60 Hz Product documentation View Indumarket specification summary (PDF)