Home Products Schneider Electric C16N47E100 Schneider Electric C16N47E100 Circuit breaker, ComPacT NSX160N, 50kA/415VAC, 4 poles, MicroLogic Vigi 7.2E trip unit 100A. Official Schneider characteristics include Range: ComPacT; Product name: ComPacT NSX; Device short name: NSX160N; Product or component type: Earth leakage circuit breaker; Device application: Distribution; Poles description: 4P; Protected poles description: 4D 3D + OSN 3D + N/2 3D; Neutral position: Left.
Details Brand: Schneider Electric Part number: C16N47E100 Series: ComPacT NSX Category: Earth leakage circuit breaker Related Schneider Electric parts Schneider Electric C16N47E160 — Circuit breaker, ComPacT NSX160N, 50kA/415VAC, 4 poles, MicroLogic Vigi 7.2E trip unit 160A Schneider Electric C16N4TM080 — Circuit breaker ComPacT NSX160N. 50kA at 415VAC. TMD trip unit 80A. 4 poles 4d Schneider Electric C16N4TM100 — Circuit breaker ComPacT NSX160N. 50kA at 415VAC. TMD trip unit 100A. 4 poles 4d Schneider Electric C16N4TM125 — Circuit breaker ComPacT NSX160N. 50kA at 415VAC. TMD trip unit 125A. 4 poles 4d Schneider Electric C16N4TM160 — Circuit breaker ComPacT NSX160N. 50kA at 415VAC. TMD trip unit 160A. 4 poles 4d circuit breaker;Compact NSX;TMD;4 poles;80 A;415 VAC;C16N6TM080 circuit breaker;Compact NSX;TMD;4 poles;100 A;415 VAC;C16N6TM100 circuit breaker;Compact NSX;TMD;4 poles;25 A;415 VAC;C16N6TM125 circuit breaker;Compact NSX;TMD;4 poles;160 A;415 VAC;C16N6TM160 Schneider Electric C16S2TM125 — Circuit breaker ComPacT NSX160S AC/DC, 70kA at 415VAC, TMD trip unit 125A, 2 poles 2d Schneider Electric C16S2TM160 — Circuit breaker ComPacT NSX160S AC/DC, 70kA at 415VAC, TMD trip unit 160A, 2 poles 2d Schneider Electric C2532D250 — Trip unit MicroLogic 2.2 for ComPacT NSX 250 circuit breakers, electronic, rating 250A, 3 poles 3d Request a quote for C16N47E100
Specifications Range ComPacT Network type AC Product name ComPacT NSX Neutral position Left Breaking capacity 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1 Device short name NSX160N Network frequency 50/60 Hz Poles description 4P Device application Distribution [In] rated current 100 A at 40 °C Utilisation category Category A Breaking capacity code N 50 kA 415 V AC Manufacturer part number C16N47E100 Product or component type Earth leakage circuit breaker Suitability for isolation Yes conforming to EN/IEC 60947-2 Protected poles description 4D 3D + OSN 3D + N/2 3D [Ue] rated operational voltage 440 V AC 50/60 Hz Product documentation View Indumarket specification summary (PDF)