Home Products Schneider Electric C16H42D100 Schneider Electric C16H42D100 circuit breaker;Compact NSX;Micrologic 2.2;4 poles;100 A;415 VAC. Official Schneider characteristics include Range: ComPacT; Product name: ComPacT NSX; Device short name: NSX160H; Product or component type: Circuit breaker; Device application: Distribution; Poles description: 4P; Protected poles description: 4D 3D + N/2 3D + N/2; Neutral position: Left.
Details Brand: Schneider Electric Part number: C16H42D100 Series: ComPacT NSX Category: Circuit breaker Related Schneider Electric parts circuit breaker;Compact NSX;Micrologic 2.2;4 poles;160 A;415 VAC;C16H42D160 Schneider Electric C16H44V100 — Circuit breaker ComPacT NSX160H, 70kA at 415VAC, MicroLogic 4.2 Vigi trip unit 100A, 4 poles 4d Schneider Electric C16H44V160 — Circuit breaker ComPacT NSX160H, 70kA at 415VAC, MicroLogic 4.2 Vigi trip unit 160A, 4 poles 4d Schneider Electric C16H47E100 — Circuit breaker, ComPacT NSX160H, 70kA/415VAC, 4 poles, MicroLogic Vigi 7.2E trip unit 100A Schneider Electric C16H47E160 — Circuit breaker, ComPacT NSX160H, 70kA/415VAC, 4 poles, MicroLogic Vigi 7.2E trip unit 160A Schneider Electric C16H4TM080 — Circuit breaker ComPacT NSX160H. 70kA at 415VAC. TMD trip unit 80A. 4 poles 4d Schneider Electric C16H4TM100 — Circuit breaker ComPacT NSX160H. 70kA at 415VAC. TMD trip unit 100A. 4 poles 4d Schneider Electric C16H4TM125 — Circuit breaker ComPacT NSX160H. 70kA at 415VAC. TMD trip unit 125A. 4 poles 4d circuit breaker;Compact NSX;TMD;4 poles;160 A;415 VAC;C16H4TM160 circuit breaker;Compact NSX;TMD;4 poles;80 A;415 VAC;C16H6TM080 circuit breaker;Compact NSX;TMD;4 poles;100 A;415 VAC;C16H6TM100 circuit breaker;Compact NSX;TMD;4 poles;25 A;415 VAC;C16H6TM125 Request a quote for C16H42D100
Specifications Range ComPacT Network type AC Product name ComPacT NSX Neutral position Left Breaking capacity 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1 Device short name NSX160H Network frequency 50/60 Hz Poles description 4P Device application Distribution [In] rated current 100 A at 40 °C Utilisation category Category A Breaking capacity code H 70 kA 415 V AC Manufacturer part number C16H42D100 Product or component type Circuit breaker Suitability for isolation Yes conforming to EN/IEC 60947-2 Protected poles description 4D 3D + N/2 3D + N/2 [Ue] rated operational voltage 690 V AC 50/60 Hz Product documentation View Indumarket specification summary (PDF)