Home Products Schneider Electric C10F44V040 Schneider Electric C10F44V040 Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 4.2 Vigi trip unit 40A, 4 poles 4d. Official Schneider characteristics include Range: ComPacT; Product name: ComPacT NSX; Device short name: NSX100F; Product or component type: Earth leakage circuit breaker; Device application: Distribution; Poles description: 4P; Protected poles description: 4D 3D + N/2 3D; Neutral position: Left.
Details Brand: Schneider Electric Part number: C10F44V040 Series: ComPacT NSX Category: Earth leakage circuit breaker Related Schneider Electric parts Schneider Electric C10F44V100 — Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 4.2 Vigi trip unit 100A, 4 poles 4d Schneider Electric C10F47E040 — Circuit breaker, ComPacT NSX100F, 36kA/415VAC, 4 poles, MicroLogic Vigi 7.2E trip unit 40A Schneider Electric C10F47E100 — Circuit breaker, ComPacT NSX100F, 36kA/415VAC, 4 poles, MicroLogic Vigi 7.2E trip unit 100A Schneider Electric C10F4TM016 — Circuit breaker ComPacT NSX100F. 36kA at 415VAC. TMD trip unit 16A. 4 poles 4d Schneider Electric C10F4TM025 — Circuit breaker ComPacT NSX100F. 36kA at 415VAC. TMD trip unit 25A. 4 poles 4d Schneider Electric C10F4TM032 — Circuit breaker ComPacT NSX100F. 36kA at 415VAC. TMD trip unit 32A. 4 poles 4d Schneider Electric C10F4TM050 — Circuit breaker ComPacT NSX100F. 36kA at 415VAC. TMD trip unit 50A. 4 poles 4d Schneider Electric C10F4TM063 — Circuit breaker ComPacT NSX100F. 36kA at 415VAC. TMD trip unit 63A. 4 poles 4d Schneider Electric C10F4TM080 — Circuit breaker ComPacT NSX100F. 36kA at 415VAC. TMD trip unit 80A. 4 poles 4d circuit breaker;Compact NSX;TMD;4 poles;100 A;415 VAC;C10F4TM100 Schneider Electric C10F6TM016 — Circuit breaker ComPacT NSX100F. 36kA at 415VAC. TMD trip unit 16A. 4 poles 3d Schneider Electric C10F6TM025 — Circuit breaker ComPacT NSX100F. 36kA at 415VAC. TMD trip unit 25A. 4 poles 3d Request a quote for C10F44V040
Specifications Range ComPacT Network type AC Product name ComPacT NSX Neutral position Left Breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 25 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1 Device short name NSX100F Network frequency 50/60 Hz Poles description 4P Device application Distribution [In] rated current 40 A at 40 °C Utilisation category Category A Breaking capacity code F 36 kA 415 V AC Manufacturer part number C10F44V040 Product or component type Earth leakage circuit breaker Suitability for isolation Yes conforming to EN/IEC 60947-2 Protected poles description 4D 3D + N/2 3D [Ue] rated operational voltage 440 V AC 50/60 Hz Product documentation View Indumarket specification summary (PDF)